Penerapan Sistem Proteksi Arus Bocor pada Instalasi Listrik Rumah Tinggal
Main Article Content
Abstract
This study focuses specifically on household needs because electricity is an inseparable part of daily needs The problems identified are how the protection system uses the earth leakage circuit breaker ELCB model for residential installations and how to apply it in residential homes quickly and straightforwardly In the current protection system the built system must work in the range of lt; 30 mA according to the general requirements of electrical installations in Indonesian abbreviated: PUIL when the muscles cannot release the conductor or are dangerous The test results of ELCB enhancements can be applied in residential homes and thus can be helpful for the community in avoiding short circuits and fires The conclusion is that the resistance measurement for the 21 participants went well and the average resistance value was 3665 k Thus the tool on the simulator works according to the operation according to PUIL < strong>< p>
Abstrak < strong>Kajian ini lebih memfokuskan secara khusus untuk kepentingan rumah tangga karena listrik menjadi hal yang tak terpisahkan dalam kebutuhan sehari hari Masalah yang dapat diidentifikasi adalah bagaimana sistem proteksi menggunakan model earth leakage circuit breaker ELCB untuk instalasi rumah tinggal dan bagaimana cara penerapannya di rumah tinggal secara mudah dan sederhana Pada sistem proteksi arus sistem yang dibangun harus bekerja pada rentang lt; 30 mA menurut persyaratan umum instalasi listrik PUIL merupakan saat dimana otot tidak sanggup melepaskan penghantar atau berbahaya Hasil pengujian piranti tambahan ELCB dapat diterapkan di rumah tinggal dan dengan demikian dapat berguna bagi masyarakat dalam menghindari hubung singkat dan kebakaran Kesimpulan pengukuran tahanan untuk para partisipan berjumlah 21 orang berjalan dengan baik dan diperoleh nilai tahanan rata rata 3665 k Dengan demikian alat pada simulator bekerja sesuai dengan operasi menurut PUIL < strong>< p>
Downloads
Article Details
Section
How to Cite
References
Alawiy M T UNISMA D T E 2013 Pengaruh Kedalaman Penanaman dan Jarak Elektroda Tambahan Terhadap Nilai Tahanan Pembumian Science Electro
American National Standard 1986 IEEE Guide for Safety in AC Substation Grounding The Institute of Electrical and Electronics Engineers Inc New York
BSN Persyaratan Umum Instalasi Listrik 2011 PUIL 2011 SNI 0225:2011 Amd 1:2013
Cooper William David 1999 Instrumentasi Elektronik dan Teknik Pengukuran Erlangga Jakarta
Fifana N Facta M Syakur A 2011 Modul Simulasi ELCB Satu Fasa Sebagai Pelindung Tegangan Sentuh Bagi Manusia Doctoral dissertation Jurusan Teknik Elektro Fakultas Teknik Undip
ISO9001 I O Earth Leakage Circuit Breaker
Kelvianto A Hariyanto A 2020 Studi Koordinasi Proteksi Arus Lebih dan Gangguan Tanah Antara Gardu Hubung Dengan Gardu Induk Menggunakan Pemutus Balik Otomatis Penyulang GJN02 Pada Gardu Gejayan Doctoral Dissertation Institut Teknologi PLN
Major R V Jasko T M Cruickshank K J 1982 The performance of sensitive earth leakage circuit breaker cores under asymmetric fault current conditions Journal of Magnetism and Magnetic Materials 26 1 3 220 222
Nahvi M Edminister J A 2004 Schaum s Easy Outlines Rangkaian Listrik Erlangga: Jakarta
Sapiie S dan Nishimo O 1986 Pengukuran dan Alat Ukur Listrik Edisi 4 Pradnya Paramita Jakarta
Sudiartha Wayan I Ketut TA 2014 Analisis Penggunaan Saklar Arus Bocor ELCB Sebagai Proteksi Tegangan Sentuh Terhadap Manusia Jurnal Logic 14 1 33 39
Suryadi A Sofwan A S 2016 Rancang Bangun Modul Simulasi ELCB Fasa Satu Sebagai Pelindung Bagi Manusia Sinergi 20 1 65 73
Syukriyadin S 2017 Sistem Proteksi Arus Bocor Menggunakan Earth Leakage Circuit Breaker Berbasis Arduino Jurnal Rekayasa Elektrika 12 3 111 118